Conta Contactos
O seu carrinho
Envio por DPD e FedEx
Precisa de ajuda? Pergunte à IA

Disjuntor modular Hager LNH3400M tetrapolar 40A curva C 6kA

Disjuntor modular Hager LNH3400M tetrapolar 40A curva C 6kA
Disjuntor modular Hager LNH3400M tetrapolar 40A curva C 6kA
39,32 €
Protecting circuits from overload and short-circuit is critical in any electrical installation. The Hager LNH3400M is a 4-pole miniature circuit breaker (MCB) with a rated current of 40 A and C tripping curve, ensuring reliable protection for cables and equipment in residential, commercial, and indu... Ler mais
Stock 24 Código 3567483 Marca HAGER Modelo LNH3400M Garantia 2 anos

Envios e devoluções

Entrega prevista Sexta-feira, Outubro 23
Receberá atualizações através do nosso sistema de seguimento detalhado
Opções de pagamento
Cartão bancárioVisaMastercardPayPalApple PayGoogle PayTransferência bancária

Protecting circuits from overload and short-circuit is critical in any electrical installation. The Hager LNH3400M is a 4-pole miniature circuit breaker (MCB) with a rated current of 40 A and C tripping curve, ensuring reliable protection for cables and equipment in residential, commercial, and industrial settings. Its 6 kA breaking capacity handles high fault currents safely.

Who is it for

Electricians and panel builders needing a robust, DIN-rail mountable MCB for three-phase circuits. Suitable for distribution boards in buildings, industrial control panels, and wherever 4-pole protection is required.

Main features

  • 4-pole (4P) design for three-phase and neutral protection
  • Rated current: 40 A
  • Tripping curve: C (for general applications with moderate inrush currents)
  • Breaking capacity: 6 kA according to EN 60898-1
  • Rated voltage: 230/400 V AC, 50/60 Hz
  • Mounting: DIN rail (EN 60715)
  • Width: 4 modules (approx. 66 mm)
  • Screw terminals for rigid (1-35 mm²) and flexible (1-25 mm²) conductors
  • Degree of protection: IP20 (terminals), IP40 (device in enclosure)
  • Operating temperature: -25 to 70 °C

Specifications

  • Number of poles: 4P
  • Rated current: 40 A
  • Tripping curve: C
  • Rated breaking capacity: 6 kA (EN 60898-1)
  • Rated voltage: 230/400 V AC
  • Frequency: 50/60 Hz
  • Mounting type: DIN rail (EN 60715)
  • Module width: 4 modules
  • Terminal capacity rigid: 1-35 mm²
  • Terminal capacity flexible: 1-25 mm²
  • Degree of protection: IP20 (terminals), IP40 (device in enclosure)
  • Electrical endurance: 10000 cycles
  • Mechanical endurance: 20000 cycles
  • Operating temperature: -25 to 70 °C
  • Connection type: screw terminals
  • Standard compliance: EN 60898-1, IEC 60898-1

Tips

Ensure the MCB's rated current matches the circuit's load and cable cross-section. For motor circuits with high inrush, consider a D-curve breaker. Always install in a suitable enclosure to maintain IP40 protection.

Especificações
Categoria
Circuit Breakers
EAN
3250614121142
Marca
Hager
Modelo
LNH3400M
MPN
LNH3400M
Peso
1 kg
Histórico de preços nos últimos 6 meses
Disjuntor modular Hager LNH3400M tetrapolar 40A curva C 6kA
Atual
39,32 €
Mais baixo
38,59 €
Mais alto
39,32 €
Variação 24 h
+0,64 €   +2%
Semana
+0,52 €   +1%
Mês
—   

Produtos populares nesta categoria

Olá, sou o assistente de IA da DistriNode. Posso ajudá-lo a encontrar produtos, comparar opções, criar orçamentos em PDF ou abrir pedidos de suporte.