PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos

PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos
PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos
PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos
PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos
176,07 €
The ATEN Basic Metered PDU PE1118SG is a 1U rack-mount power distribution unit with 18 AC outlets designed for reliable power delivery and monitoring in IT environments. It features a built-in surge protection module and overcurrent protection to reduce equipment downtime. Dual 3-digit 7-segment dis... Ler mais
Stock 3 Código 1476819 Marca ATEN Modelo PE1118SG-AT-G Garantia 2 anos

Envios e devoluções

Entrega prevista Terça-feira, Novembro 3
Receberá atualizações através do nosso sistema de seguimento detalhado
Opções de pagamento
Cartão bancárioVisaMastercardPayPalApple PayGoogle PayTransferência bancária

The ATEN Basic Metered PDU PE1118SG is a 1U rack-mount power distribution unit with 18 AC outlets designed for reliable power delivery and monitoring in IT environments. It features a built-in surge protection module and overcurrent protection to reduce equipment downtime. Dual 3-digit 7-segment displays provide real-time input voltage and output current readings. The unit includes a 3 m power cable and supports 100–240 V operation with a maximum current rating of 10 A.

Advantages

The PE1118SG combines compact 1U form factor and rack-mount compatibility to save space and reduce cable clutter. Integrated surge protection safeguards connected equipment from sudden voltage spikes, while overcurrent protection helps prevent damage and minimize downtime. Real-time monitoring via dual 3-digit displays allows quick confirmation of input voltage and output current for centralized power management.

Suitable for (tasks / use cases)

  • Power distribution for server racks in data centers and server rooms
  • Supplying power to network equipment such as switches and routers
  • Powering storage systems and KVM switches in IT cabinets

Key specifications

  • Model: ATEN PE1118SG
  • Form factor: 1U rack-mount
  • Outlets: 18 AC outlets (IEC or NEMA configurations available)
  • Surge protection: built-in module
  • Monitoring: dual 3-digit 7-segment displays for input voltage and output current
  • Cable length: 3 m
  • Input voltage: 100–240 V
  • Maximum current: 10 A

How to use

Install the PE1118SG in a 1U space within a standard rack using the included rack-mount hardware. Connect the unit to a suitable AC power source using the supplied 3 m cable, observing the 100–240 V and 10 A limits. Plug IT equipment into the PDU outlets, and monitor the input voltage and output current on the dual 3-digit displays to verify proper power status. Ensure outlet wiring and load distribution follow your site electrical policies.

Recommendations

For reliable operation, avoid exceeding the 10 A maximum current rating and balance loads across outlets. Place the PDU in a properly ventilated rack space and verify surge protection status periodically. Use the front displays for quick checks, and integrate PDU monitoring into your standard maintenance routine.
Destaques principais
  • Power distribution for server racks in data centers and server rooms
  • Supplying power to network equipment such as switches and routers
  • Powering storage systems and KVM switches in IT cabinets
  • Model: ATEN PE1118SG
  • Form factor: 1U rack-mount
  • Outlets: 18 AC outlets (IEC or NEMA configurations available)
  • Surge protection: built-in module
  • Monitoring: dual 3-digit 7-segment displays for input voltage and output current
  • Cable length: 3 m
  • Input voltage: 100–240 V
  • Maximum current: 10 A
Especificações
Altitude de funcionamento
0 - 3000 m
Altura
88.5 mm
Cabos incluídos
AC
Capacidade de carga
2400 VA
Capacidade do rack
1U
Certificados de conformidade
CE, Low Voltage Directive (LVD)
Comprimento do cabo
3 m
Conformidade em sustentabilidade
Yes
Conteúdo da embalagem
1x Basic Metered 1U PDU with Surge Protection 1x Power Cord 1x User Instructions
Cor do produto
Black
Corrente máxima
10 A
Ecrã
LCD
Ficha de alimentação
C14 coupler
Frequência de entrada CA
50 - 60 Hz
Funções de proteção elétrica
Over current
Largura
44.4 mm
Manual
Yes
Monitorização
Current
Montagem em rack
Yes
Número de tomadas CA
18 AC outlet(s)
País de origem
China
Peso
1.3 kg
Portas Ethernet LAN (RJ-45)
1
Profundidade
440 mm
Proteção contra sobretensões
Yes
Temperatura de armazenamento (T-T)
-20 - 60 °C
Temperatura de funcionamento (T-T)
0 - 40 °C
Tensão nominal de entrada
100 - 240 V
Tipos de PDU
Basic, Metered
Tipos de tomadas
C13 coupler

Documento

Abrir documento

Folheto

Abrir documento
Histórico de preços nos últimos 6 meses
PDU básica com medição ATEN PE1118SG 1U 18 saídas AC proteção contra picos
Atual
176,07 €
Mais baixo
174,50 €
Mais alto
181,62 €