Conta Contactos
O seu carrinho
Envio por DPD e FedEx
Precisa de ajuda? Pergunte à IA

Sistema UPS Digitus OnLine 10 kVA 10 kW

Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
Sistema UPS Digitus OnLine 10 kVA 10 kW
839,84 €
The DIGITUS OnLine 10 kVA 10 kW UPS is a parallel-redundant, double-conversion rack/tower system designed to provide continuous, fail-safe power for industrial and network-critical applications. It delivers a high power factor (1.0) and high online efficiency to maximize usable output and reduce ene... Ler mais
Stock 1 Código 325050 Marca DIGITUS Modelo DN-170107 Garantia 2 anos

Envios e devoluções

Entrega prevista Quarta-feira, Outubro 14
Receberá atualizações através do nosso sistema de seguimento detalhado
Opções de pagamento
Cartão bancárioVisaMastercardPayPalApple PayGoogle PayTransferência bancária

The DIGITUS OnLine 10 kVA 10 kW UPS is a parallel-redundant, double-conversion rack/tower system designed to provide continuous, fail-safe power for industrial and network-critical applications. It delivers a high power factor (1.0) and high online efficiency to maximize usable output and reduce energy loss. The unit is compact (2U rack height) with a metal housing and supports external battery modules (ordered separately, part number DN-170108) to extend runtime. The UPS includes network management options and a user-friendly LCD for status monitoring and configuration. It has no internal batteries and supports parallel/redundant operation of up to four devices for increased availability.

Advantages

High power factor (1.0) and elevated active output allow more connected loads within the rated capacity, saving rack space and reducing system cost. The UPS operates with high efficiency in online double-conversion mode, improving energy management and lowering heat dissipation. A clear LCD display simplifies installation, configuration and daily operation. Compact rack/tower design requires only 2U of rack space. Multiple communication interfaces (RS232/USB, parallel port, SNMP slot) enable remote monitoring and control. Automatic battery self-test, fan speed control and REPO (Remote Emergency Power Off) increase component life and provide safe shutdown in emergencies. The system supports parallel or redundant configurations (up to four units) and external battery cabinets for scalable runtime.

Suitable for

  • Server rooms and data centers requiring high availability
  • Network edge and telecommunications equipment
  • Industrial control systems and automation
  • Critical infrastructure and monitoring systems

Key specifications

  • Model: DIGITUS OnLine 10 kVA 10 kW (MPN: DN-170107, EAN: 4016032473558)
  • Topology: Double-conversion (online) UPS
  • Rated output power: 10 kW
  • Power factor: 1.0
  • Form factor: Rack/tower, 2U height
  • Dimensions (W × D × H): 440 × 620 × 86.5 mm
  • Weight: 18 kg
  • Communication: RS232, USB Type-B, parallel port, SNMP slot
  • Batteries: External battery modules required (DN-170108); no internal batteries
  • Battery recharge time: 8 hours; charging current: 1 A

How to use

Install the UPS in a standard 19-inch rack using 2U of space or place it as a tower on a stable, ventilated surface. Connect the input mains and critical loads according to the site electrical design and local regulations. Fit external battery modules (DN-170108) if runtime extension is required; internal batteries are not supplied. Use the LCD display to view status, alarms and configuration menus. For remote monitoring and management, connect the USB Type-B or RS232 port and install compatible management software or insert an SNMP card in the dedicated slot. Configure parallel operation when deploying more than one unit, following the manufacturer’s parallel-connection procedure.

Recommendations

Place the UPS in a clean, temperature-controlled environment with adequate ventilation. Verify compatibility of external battery modules before installation. Schedule regular battery self-tests and monitor fan operation via the LCD or network management to ensure continuous availability.
Destaques principais
  • Server rooms and data centers requiring high availability
  • Network edge and telecommunications equipment
  • Industrial control systems and automation
  • Critical infrastructure and monitoring systems
  • Model: DIGITUS OnLine 10 kVA 10 kW (MPN: DN-170107, EAN: 4016032473558)
  • Topology: Double-conversion (online) UPS
  • Rated output power: 10 kW
  • Power factor: 1.0
  • Form factor: Rack/tower, 2U height
  • Dimensions (W × D × H): 440 × 620 × 86.5 mm
  • Weight: 18 kg
  • Communication: RS232, USB Type-B, parallel port, SNMP slot
  • Batteries: External battery modules required (DN-170108); no internal batteries
  • Battery recharge time: 8 hours; charging current: 1 A
Especificações
Altura
86.5 mm
Arranque a frio
Yes
Bateria hot-swap
Yes
Capacidade de potência de saída
6 kVA
Capacidade do rack
2U
Código da pauta aduaneira do Reino Unido
85044086
Código de proteção internacional (IP)
IP20
Código do Sistema Harmonizado (HS)
85078000
Conector de corte de emergência (EPO)
Yes
Cor do produto
Black
Corrente de carregamento
1 A
Corte de emergência (EPO)
Yes
Distorção harmónica total (THD) da corrente de entrada
5 %
Distorção harmónica total (THD) da tensão de saída
5 %
Eficiência
93.5 %
Fator de crista
3:1
Fator de potência
0.99
Ficha de alimentação
Hardwire
Forma de onda
Pure sine
Formato
Rackmount/Tower
Frequência de entrada
45/66
Frequência de saída
50/60
Largura
440 mm
Largura da embalagem
615 mm
Manual
Yes
Material da carcaça
Metal
Modo ECO
Yes
Nível de ruído
55 dB
Número de fases de entrada
1
Número de fases de saída
1
Número de pilhas suportadas
20
Número de portas USB 2.0
1
País de origem
China
Peso
18 kg
Peso da embalagem
20600 g
Porta USB
Yes
Potência de saída
10000 W
Profundidade
620 mm
Profundidade da embalagem
765 mm
Regulação da frequência de saída
1
Regulação da tensão de saída
5
Tamanho (polegadas)
19 "
Temperatura de funcionamento (T-T)
0 - 40
Tempo de recarga da bateria
8 h
Tempo de resposta
20 ms
Tensão de funcionamento de entrada (máx.)
276 V
Tensão de funcionamento de entrada (mín.)
120 V
Tensão de funcionamento de saída (máx.)
240 V
Tensão de funcionamento de saída (mín.)
208 V
Tipo de conector USB
USB Type-B
Tipo de ecrã
LCD + LED
Tipo de refrigeração
Active
Topologia da UPS
Double-conversion (Online)
Ventoinha integrada
Yes
Volume da embalagem
100682 cm³

Folheto

Abrir documento

Documento

Abrir documento
Histórico de preços nos últimos 6 meses
Sistema UPS Digitus OnLine 10 kVA 10 kW
Atual
839,84 €
Mais baixo
799,11 €
Mais alto
1 046,57 €
Variação 24 h
+38,86 €   +5%
Semana
+37,80 €   +5%
Mês
+28,27 €   +3%

Produtos populares nesta categoria

Olá, sou o assistente de IA da DistriNode. Posso ajudá-lo a encontrar produtos, comparar opções, criar orçamentos em PDF ou abrir pedidos de suporte.