Conta Contactos
O seu carrinho
Envio por DPD e FedEx
Precisa de ajuda? Pergunte à IA

Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m

Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
17,83 €
The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 10m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. With S/FTP (shielded foil over pair with overall braid) construction and PiMF (pair in metal foil) design, the cable provides... Ler mais
Stock 60 Código 310746 Marca INLINE Modelo 76800R Garantia 2 anos

Envios e devoluções

Entrega prevista Quinta-feira, Outubro 22
Receberá atualizações através do nosso sistema de seguimento detalhado
Opções de pagamento
Cartão bancárioVisaMastercardPayPalApple PayGoogle PayTransferência bancária

The InLine Patch Cable S/FTP PiMF Cat.6A halogen free 500MHz red 10m is a high-performance patch cable engineered for professional cabling in Gigabit and 10 Gigabit networks. With S/FTP (shielded foil over pair with overall braid) construction and PiMF (pair in metal foil) design, the cable provides improved protection against electromagnetic interference for stable signal transmission up to 500 MHz. The halogen-free jacket reduces toxic emissions in case of fire, and RJ-45 connectors on both ends ensure compatibility with standard network equipment.

Advantages

The S/FTP PiMF shielding minimizes crosstalk and external interference, supporting reliable high-speed data transfer. Category 6A specification and 500 MHz bandwidth enable use in demanding Gigabit and 10 Gigabit applications. The halogen-free sheath improves safety in enclosed environments such as data centers and server racks. A 10 m length and standard RJ-45 terminations provide flexible installation options and compatibility with existing infrastructure.

Suitable for

  • Data centers and server rack connections
  • High-speed Ethernet links (Gigabit and 10 Gigabit)
  • Structured cabling in commercial and enterprise networks

Key specifications

  • Category: Cat.6A
  • Shielding: S/FTP PiMF
  • Bandwidth: up to 500 MHz
  • Length: 10 m
  • Connectors: RJ-45 to RJ-45
  • Colour: Red
  • Halogen-free jacket
  • Brand: InLine
  • MPN: 76800R
  • EAN: 4043718088683

How to use

Connect one RJ-45 connector of the InLine Cat.6A patch cable to the network port of your switch, router or patch panel and the other end to the target device or port. Ensure connectors are fully inserted until they click to secure the connection. Route the cable through cable management trays or along rack paths to avoid sharp bends and tension; maintain the recommended bend radius for Cat.6A cabling to preserve performance.

Recommendations

For optimal performance, use the cable within a structured cabling system that meets Cat.6A standards, avoid excessive bending and mechanical stress, and keep away from strong electromagnetic sources. Verify connector seating and test links after installation to confirm Gigabit or 10 Gigabit operation.
Destaques principais
  • Assignment according to TIA/EIA 568B2.1
  • cable construction S/FTP (PiMf) 4x2xAWG26/7
  • overall braided shield with paired foil shield
  • Cable sheath halogen free, LSZH, conform to standards IEC 60332-1-2, IEC 60754-1, IEC 60754-2, IEC 61034 IEC332-1
  • plug RJ45 (8P8C) with 50µ" gold plated contacts and with special design and latch protection
  • blue colored plug for easy distinction
  • For Gigabit and 10 Gigabit applications
  • to 500MHz: 100% Cat.6 test and 100% Cat.6A test (Fluke Channel Link Test) including the attached test protocol and serial number
  • in reclosable PE bag with EAN code
  • 10 m
  • RJ-45 Male
  • RJ-45 Male
  • Cat6a S/FTP (S-STP)
  • Red
Especificações
Altura
15 mm
Altura da embalagem
48 mm
Bitola do fio (AWG)
26
Blindagem do cabo
S/FTP (S-STP)
Comprimento do cabo
10 m
Conector 1
RJ-45
Conector 2
RJ-45
Cor do produto
Red
Dimensões (LxAxP)
12 x 10000 x 15 mm
Género do conector 1
Male
Género do conector 2
Male
Largura
12 mm
Largura da embalagem
200 mm
Material da bainha
Low smoke zero halogen (LSZH)
Material do condutor
Copper
Norma do cabo
Cat6a
Peso
392 g
Peso da embalagem
335 g
Profundidade
10000 mm
Profundidade da embalagem
245 mm
Volume da embalagem
2400 cm³

Folheto

Abrir documento

Documento

Abrir documento
Histórico de preços nos últimos 6 meses
Cabo de rede InLine S/FTP PiMF Cat.6A sem halogéneos 500MHz vermelho 10m
Atual
17,83 €
Mais baixo
15,53 €
Mais alto
27,63 €
Variação 24 h
+1,37 €   +8%
Semana
+1,34 €   +8%
Mês
+1,41 €   +9%

Produtos populares nesta categoria

Olá, sou o assistente de IA da DistriNode. Posso ajudá-lo a encontrar produtos, comparar opções, criar orçamentos em PDF ou abrir pedidos de suporte.